Features
- Adopting IGBT rectification technology, high input power factor, low input current harmonics, friendly to the grid
- Using battery intermittent charging function, avoid the battery from long-term floating charge and vulcanization,
- and extend the battery life
- Innovative battery feed to grid discharge function enables high current battery discharge test without dummy load
- Innovative UPS capacitance online monitoring function in display, early warning of capacitor anomalies
- Innovative BLOCK battery sharing function realizes the redundancy of UPS functional components and improves the availability of parallel system
- Ultra-wide range of battery number adjustability, individual battery failure can be removed on site and quickly restore the backup power supply
- Compatible with lithium-ion batteries, flywheels, super capacitors and other new energy storage media
- Suitable for industrial load: 100% unbalanced load, 100% non-linear load, with energy backfilling absorption function
- Circuit board with anti-paint coating treatment to resist moisture, mildew and salt spray
- Isolation air duct design for power circuit and magnetic devices to ensure good heat dissipation
- The machine adopts low-smoke halogen-free flame retardant cables
TTB-i Series
MODEL | TTB-i 3310 | TTB-i 3320 | TTB-i 3330 | TTB-i 3340 | TTB-i 3350 | TTB-i 3360 | TTB-i 3380 | TTB-i 33100 | TTB-i 33120 | TTB-i 33160 | TTB-i 33200 |
INPUT | |||||||||||
Input Voltage (Vac) | 380/400/415 (L-L) | ||||||||||
Voltage Range (Vac) | -25%~+25% | ||||||||||
Frequency (Hz) | 50/60±10% | ||||||||||
Bypass tracking range(Hz) | 50/60±10% (programmable) | ||||||||||
Phase | 4W+PE | ||||||||||
Battery voltage(VDC) | 348~480 | ||||||||||
OUTPUT | |||||||||||
Power Factor (PF) | Power Factor (PF) | ||||||||||
Voltage (Vac) | Voltage (Vac) | ||||||||||
Frequency (Hz) | Frequency (Hz) | ||||||||||
Wave | Wave | ||||||||||
Overload | Overload | ||||||||||
Efficiency | Efficiency | ||||||||||
OTHERS | |||||||||||
Communication | Dry Contact, RS485, MODBUS | ||||||||||
Alarm | Abnormal AC input, low battery, Overload | ||||||||||
Option | DC cold start, Parallel, Waterproof Roof, SNMP/RS232, Lightening Protection C | ||||||||||
Protection | Low battery voltage, Overload, Short circuit, over temperature, low input voltage | ||||||||||
Working Temperature (°C) | -5 ~40 | ||||||||||
Relative Humidity | 0%~95% (RH) | ||||||||||
Noise (dB) | <65 | ||||||||||
Dimension (W×D×H)(mm) | 600×800×2000 | 1000×800×2000 | |||||||||
Weight (kg) | 350 | 380 | 420 | 445 | 500 | 525 | 630 | 670 | 800 | 1020 | 1150 |