Rectifier Chargers GR (B)19inch

Rectifier Chargers

GR (SF/D)

GR(HS)

GR (B) 19 inch

GR (B)

The GR(19 inch) series is an advanced rack-based charger in the TECNED GR product family available with central monitoring and control options. It strictly adheres to a truly industrial design and is built for 20 years operational life-time.

TECNED Industrial grade rectifier/chargers are based on transformer technology for robustness and endurance. The input isolation transformer protects the semiconductors against spikes, surges and filters noise. Transformer based rectifier/charger technology combined with blocking diodes in the output offer a longer service life and higher degree of protection of your critical load.

Based on this topology, TECNED provides a highly reliable charger / inverter product combination designed for demanding operating environments.

The availability can be further increased with 2 or more rectifier/charger modules in parallel operation mode.

Like all GR-models, the GR(19inch) series is short circuit proof, includes current limit, high voltage protection and potential free contacts.

rectifier-chargers-gr-b-19-inch

Tecned GR(B) 19 inch Specifications

1- INPUT
Input voltage single phase 110 / 120 / 200 / 220 / 230 / 240 / 277V, (2W+E)
Input voltage three phase 208 / 220 / 240 / 380 / 400 / 415 / 480V, (3W+E)
Input voltage range 15%/-20% (20% start battery operation)
nominal input frequency [Hz] 50/60
allowable frequency range [Hz] 40-70
input current THD [%] <10
power factor PF 0.98
overall efficiency [%] Up to 95% (depending on DC bus voltage)
galvanic isolation Yes (input isolation transformer)
2- OUTPUT
nominal output voltage [Vdc] 24, 48, 60, 110 (125), 220 (240), 380 Vdc
Battery charging characteristic IU (DIN 41773), T° compensated Battery charging characteristic floating voltage
DC voltage range [Vdc] 24 – 380Vdc
Float charge setting (Cell) [Vdc] 1.40-1.42V for Ni-cd or 2.17 -2.27V for Lead acid
output current I-nominal [A] 10A to 200A (depending on DC voltage level)
battery charge current setting [%] 0.1C to max current adustable with dip-switch
output voltage regulation [%] < 1 ( 0.5% static)
load step response time [ms] < 200 (0-to 100%)
ripple voltage (without battery) [%] <5% with 1Ph input / < 2% with 3Phase input
current limiting [%] Yes
current accuracy [%] 2%
long-term stability [%] 0.15% for 1000 Hrs
3 – PROTECTION
soft start inrush current limit
input (AC) short circuit protection by MCB
input (AC) overload protection electronically limited
output (DC) short circuit protection by MCB
output (DC) overvoltage alarm (DC high) / auto-off / manual reset
battery overload/short circuit protection by MCB and battery low voltage alarm
4 – BASIC USER INTERFACE
  • LED lamp Operation ( green)
  • LED lamp Battery Operation (yellow)
  • LED lamp General Failure (red)
  • LED lamp DC high alarm (red)
  • LED lamp DC low alarm (red)
  • LED lamp Utility Failure (red)
  • LED lamp Fan Failure (red)
  • button on
  • button off
  • button buzzer off
  • button lamp test
  • 5 – EXTERNAL CONTACT (max 250VAC or 30VDC / 2A)
    general alarm
    6 – ENCLOSURE
    finish : AluZinc 2mm. / AluZinc 1.2mm.
    7 – DIMS (hxwxd) (mm)
    1-phase input : 19 Inch / 5U high / 700mm deep
    3-phase input : 19 inch / 7U high / 700mm deep
    weight : 50-110kG depending on configuration
    fans : front access for replacement
    cable entry : back, terminal connection
    protection : IP 20
    8 – STANDARDS
    ISO9001 : Quality management systems
    IEC- 60146 : Semiconductor converters – General requirements and line commutated converters
    EMC 55011 : Industrial, scientific, and medical (ISM) radio-frequency equipment—Radio disturbance characteristics—Limits and methods of measurement; Amendment A1:1999 to EN55011:1998.
    IEC- 62040-1 : Uninterruptible power systems (UPS) Part 1: General and safety requirements for UPS
    IEC 61000-3-12 : Electromagnetic compatibility (EMC) – Part 3-12: Limits -Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current>16 A and ≤ 75 A
    IEC/61000-6-5 : Low voltage AC Surge 1.2/50 μs, 2 kV line to ground, 1kV line to line (equipment installed in power stations and MV substations. Low voltage DC Surge 1.2/50 μs, 2 kV line to ground, 1 kV line to line
    9 – ENVIRONMENT
    storage temperature : -25 to + 70 °C
    operating temperature : -10 to + 40 °C
    humidity : max. 95%
    installation altitude : < 1000 meter at full rate
    derating : 7% per 1000 meter to 4000m
    audible noise : 55 dBA
    10 – TECHNOLOGY
  • High power factor IGBT/SCR conversion technology with very low input THDI and build-in galvanic separation transformer.
  • Charging characteristic according DIN 41773 (UI)
  • High reliable due to failsafe control system and protection circuits